Manufacturer: X-Charger
Part Number: XC-01
This Product is available in our warehouse
Customer Questions & Answers: ( 6 )
Choose brand and model
![]() | FULL AUTOMATIC Connect and Forget 12V Charger, performs Steps Charging and Maintenance. Just plug it in and it does everything itself. You can leave it connected for long periods without any manual intervention. |
![]() | For all types of 12V Lead-Acid batteries WET, MF, GEL, AGM, VRLA. |
![]() | XC-01, 180cm power cord ending with CEE 7/16 Plug (Europlug), 140cm battery cord ending with SAE Connector. ![]() ![]() ![]() |
![]() | Weatherproof Permanent Battery Lead, 3A fused, length 60cm. Terminals: 8,5mm Eyelet > SAE Connector. |
![]() | Fast Connection Battery Lead , length 60cm. Terminals: Clamps > SAE Connector.. |
![]() | BATTERY CHECK: If battery voltage is over 3V Starts Charging, if battery voltage is under 3V stands by. |
![]() | BULK CHARGE : Charging using 1A Max Current until battery voltage reaches 13,5V. |
![]() | CONSTANT CHARGE: Charging using 0,6A, battery slowly reaches the maximum capacity without overheating (it is very important for wet batteries). |
![]() | ABSORPTION - FULL CHARGE : once battery reaches full capacity (about 14.4 / 14.6V, depending on the status and capacity of every battery), the current declines quickly until the voltage reaches 14.7V. |
![]() | CONTROL : monitoring if the voltage drops below 13,7V. |
![]() | PULSE MAINTENANCE: if the voltage drops below 13,7V, starts pulse maintaining, providing current pulses of about 0.2 - 0.4A to keep the battery charged at 95-100%. |
![]() | CONSTANT CHARGE MAINTENANCE: if the voltage drops below 13,5V, starts constant charge maintenance at 0,6A; once battery reaches 13,5V starts pulse maintenance till reaching about 13,7V, and then returns to STEP 6. This functions starts only when battery can't keep the maximum charge. Does not necessarily indicate a problem with the battery. |
![]() | CHARGE REACTIVATION : if the above function does not produce any result and the voltage drops below 12V, starts bulk charge at 1A until voltage reaches 13.5V, it is like it comes back to STEP 2. This step is a sign of a critical battery problem. |
STATUS | Voltage | Current | LED | ||
POWER | CHARGE | MAINTENANCE | |||
STANDBY | 0 | 0 | ![]() | ![]() | ![]() |
BATTERY CHECK | < 3V | 0 | ![]() | ![]() | ![]() |
> 3V | 1A | ![]() | ![]() | ![]() | |
BULK CHARGE | 3V>13,5V | 1A | ![]() | ![]() | ![]() |
CONSTANT CHARGE | 13,5V > 14,4V | 0,6A | ![]() | ![]() | ![]() |
ABSORTION - FULL CHARGE | 14,4V > 14,7V | 0,6A > 0,1A | ![]() | ![]() | ![]() |
CONTROL | 14,7V > 13,7V | 0A | ![]() | ![]() | ![]() |
PULSE MAINTENANCE | 13,7V - 14,4V | 0,2A - 0,4A | ![]() | ![]() | ![]() |
CONSTANT CHARGE MAINTENANCE | <13,5V | 0,6A | ![]() | ![]() | ![]() |
CHARGE REACTIVATION | <12V | 1A | ![]() | ![]() | ![]() |
Charger can stay connected to the battery for long periods. In case of power blackout, once power is restored, charger automatically reactivates starting from the battery check. In any case don't leave batteries unattended and connected for long periods. Wet batteries could need water refill.